1.2 Normal Voltage Range: 200/240Vac.
1.3 Input Frequency Range: 47-66 Hz.
1.4 Max Input AC current: 12A MAX. @ 230Vac.
1.5 Inrush Current: No hazards at AC input 230VACA and 25° start
1.6 Efficiency: Meet 80 plus Bronze requirement at 230Vac input
Output :
The continuous total output power is 1850W max.
Peak currents may last up to 12 seconds with not more than one occurrence per minute.
Add 0.1uF and 10uF capacitors across output terminal during ripple & noise test.
Protections:
When OVP ,OPP or short protection is triggered, the main outputs will be latched off. The main outputs can be reset by cycling the
DC remote on/off or AC power.
+5Vsb output is auto recovery when fault condition removed.
.1 OVER VOLTAGE PROTECTION
+3.3V output 4.5 Vmax.
+5.0V output 7.0 Vmax.
+12.0V output 15.6 Vmax.
3.2 SHORT PROTECTION
All output to GND.
3.3 OVER POWER PROTECTION
Foldback at 110%~150% over peak load.